Test Case Output

Back to test-testshield-pwm-and-adc Results ^

Target: LPC1768
Test: test-testshield-pwm-and-adc
Test Case: Test PWM Maintains Duty Cycle (freq = 1kHz)

{{__testcase_start;Test PWM Maintains Duty Cycle (freq = 1kHz)}}, queued...
[+33276ms][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[+34391ms][SERI][TXD] {{frequency;1000.0}}
[+34402ms][SERI][TXD] {{duty_cycle;0.7499981250046875}}
[+34422ms][CONN][RXD] Expected PWM frequency was 1000 Hz (+- 21 Hz) and duty cycle was 75.00% (+-0.10%), host measured frequency 1000 Hz and duty cycle 75.00%
[+34422ms][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[+35519ms][SERI][TXD] {{frequency;40000.0}}
[+35529ms][SERI][TXD] {{duty_cycle;0.742080644798388}}
[+35549ms][CONN][RXD] Expected PWM frequency was 40000 Hz (+- 80 Hz) and duty cycle was 75.00% (+-0.40%), host measured frequency 40000 Hz and duty cycle 74.21%
[+35560ms][CONN][RXD] :124::FAIL: Expected 0.750000 Was 0.742081
[+35560ms][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[+36654ms][SERI][TXD] {{frequency;200.0}}
[+36664ms][SERI][TXD] {{duty_cycle;0.7499981250046875}}
[+36684ms][CONN][RXD] Expected PWM frequency was 200 Hz (+- 20 Hz) and duty cycle was 75.00% (+-0.10%), host measured frequency 200 Hz and duty cycle 75.00%
[+36694ms][CONN][INF] found KV pair in stream: {{__testcase_finish;Test PWM Maintains Duty Cycle (freq = 1kHz);0;1}}