Back to test-testshield-pwm-and-adc Results ^
Target: NUCLEO_H563ZI
Test: test-testshield-pwm-and-adc
Test Case: Test PWM frequency and duty cycle (freq = 50 Hz)
{{__testcase_start;Test PWM frequency and duty cycle (freq = 50 Hz)}}, queued...
[1726208974.38][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1726208976.65][SERI][TXD] {{frequency;50.0}}
[1726208976.66][SERI][TXD] {{duty_cycle;0.05319118351102061}}
[1726208976.68][CONN][RXD] Expected PWM frequency was 50 Hz (+- 20 Hz) and duty cycle was 5.32% (+-0.10%), host measured frequency 50 Hz and duty cycle 5.32%
[1726208976.68][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1726208978.90][SERI][TXD] {{frequency;50.0}}
[1726208978.92][SERI][TXD] {{duty_cycle;0.16010979986275017}}
[1726208978.94][CONN][RXD] Expected PWM frequency was 50 Hz (+- 20 Hz) and duty cycle was 16.01% (+-0.10%), host measured frequency 50 Hz and duty cycle 16.01%
[1726208978.94][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1726208981.20][SERI][TXD] {{frequency;50.0}}
[1726208981.21][SERI][TXD] {{duty_cycle;0.661427923215096}}
[1726208981.23][CONN][RXD] Expected PWM frequency was 50 Hz (+- 20 Hz) and duty cycle was 66.14% (+-0.10%), host measured frequency 50 Hz and duty cycle 66.14%
[1726208981.23][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1726208983.49][SERI][TXD] {{frequency;50.0}}
[1726208983.51][SERI][TXD] {{duty_cycle;0.8503926870091413}}
[1726208983.53][CONN][RXD] Expected PWM frequency was 50 Hz (+- 20 Hz) and duty cycle was 85.04% (+-0.10%), host measured frequency 50 Hz and duty cycle 85.04%
[1726208983.53][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1726208985.79][SERI][TXD] {{frequency;50.0}}
[1726208985.80][SERI][TXD] {{duty_cycle;0.6394992006259992}}
[1726208985.82][CONN][RXD] Expected PWM frequency was 50 Hz (+- 20 Hz) and duty cycle was 63.95% (+-0.10%), host measured frequency 50 Hz and duty cycle 63.95%
[1726208985.83][CONN][RXD] >>> 'Test PWM frequency and duty cycle (freq = 50 Hz)': 1 passed, 0 failed
[1726208985.83][CONN][RXD] :0::PASS
[1726208985.83][CONN][RXD]
[1726208985.83][CONN][INF] found KV pair in stream: {{__testcase_finish;Test PWM frequency and duty cycle (freq = 50 Hz);1;0}}