Back to test-testshield-pwm-and-adc Results ^
Target: NUCLEO_L452RE_P
Test: test-testshield-pwm-and-adc
Test Case: Test PWM Maintains Duty Cycle (freq = 1kHz)
{{__testcase_start;Test PWM Maintains Duty Cycle (freq = 1kHz)}}, queued...
[1725236288.80][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1725236290.99][SERI][TXD] {{frequency;1000.0}}
[1725236291.00][SERI][TXD] {{duty_cycle;0.7499128126089842}}
[1725236291.02][CONN][RXD] Expected PWM frequency was 1000 Hz (+- 20 Hz) and duty cycle was 75.00% (+-0.10%), host measured frequency 1000 Hz and duty cycle 74.99%
[1725236291.02][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1725236293.23][SERI][TXD] {{frequency;40010.0}}
[1725236293.24][SERI][TXD] {{duty_cycle;0.750029062463672}}
[1725236293.27][CONN][RXD] Expected PWM frequency was 40000 Hz (+- 20 Hz) and duty cycle was 75.00% (+-0.40%), host measured frequency 40010 Hz and duty cycle 75.00%
[1725236293.27][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1725236295.46][SERI][TXD] {{frequency;200.0}}
[1725236295.47][SERI][TXD] {{duty_cycle;0.7500165624792969}}
[1725236295.49][CONN][RXD] Expected PWM frequency was 200 Hz (+- 20 Hz) and duty cycle was 75.00% (+-0.10%), host measured frequency 200 Hz and duty cycle 75.00%
[1725236295.49][CONN][INF] found KV pair in stream: {{__testcase_finish;Test PWM Maintains Duty Cycle (freq = 1kHz);1;0}}