Test Case Output

Back to test-testshield-pwm-and-adc Results ^

Target: NUCLEO_L452RE_P
Test: test-testshield-pwm-and-adc
Test Case: Test PWM frequency and duty cycle (freq = 1 kHz)

{{__testcase_start;Test PWM frequency and duty cycle (freq = 1 kHz)}}, queued...
[1725236237.41][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1725236239.59][SERI][TXD] {{frequency;1000.0}}
[1725236239.60][SERI][TXD] {{duty_cycle;0.6189179763525295}}
[1725236239.62][CONN][RXD] Expected PWM frequency was 1000 Hz (+- 20 Hz) and duty cycle was 61.89% (+-0.10%), host measured frequency 1000 Hz and duty cycle 61.89%
[1725236239.62][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1725236241.80][SERI][TXD] {{frequency;1000.0}}
[1725236241.82][SERI][TXD] {{duty_cycle;0.41495323130846085}}
[1725236241.84][CONN][RXD] Expected PWM frequency was 1000 Hz (+- 20 Hz) and duty cycle was 41.49% (+-0.10%), host measured frequency 1000 Hz and duty cycle 41.50%
[1725236241.84][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1725236244.03][SERI][TXD] {{frequency;1000.0}}
[1725236244.04][SERI][TXD] {{duty_cycle;0.7679702900371375}}
[1725236244.06][CONN][RXD] Expected PWM frequency was 1000 Hz (+- 20 Hz) and duty cycle was 76.80% (+-0.10%), host measured frequency 1000 Hz and duty cycle 76.80%
[1725236244.06][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1725236246.28][SERI][TXD] {{frequency;1000.0}}
[1725236246.29][SERI][TXD] {{duty_cycle;0.9825187718515351}}
[1725236246.31][CONN][RXD] Expected PWM frequency was 1000 Hz (+- 20 Hz) and duty cycle was 98.25% (+-0.10%), host measured frequency 1000 Hz and duty cycle 98.25%
[1725236246.31][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[1725236248.49][SERI][TXD] {{frequency;1000.0}}
[1725236248.50][SERI][TXD] {{duty_cycle;0.48714564106794866}}
[1725236248.53][CONN][RXD] Expected PWM frequency was 1000 Hz (+- 20 Hz) and duty cycle was 48.71% (+-0.10%), host measured frequency 1000 Hz and duty cycle 48.71%
[1725236248.53][CONN][INF] found KV pair in stream: {{__testcase_finish;Test PWM frequency and duty cycle (freq = 1 kHz);1;0}}