Back to test-testshield-pwm-and-adc Results ^
Target: NUCLEO_U083RC
Test: test-testshield-pwm-and-adc
Test Case: Test reading analog values with the ADC
{{__testcase_start;Test reading analog values with the ADC}}, queued...
[+657ms][CONN][RXD] PWM duty cycle of 0.0% produced an ADC reading of 0.1% (expected 0.0%)
[+708ms][CONN][RXD] PWM duty cycle of 10.0% produced an ADC reading of 9.8% (expected 10.0%)
[+760ms][CONN][RXD] PWM duty cycle of 20.0% produced an ADC reading of 20.6% (expected 20.0%)
[+811ms][CONN][RXD] PWM duty cycle of 30.0% produced an ADC reading of 30.3% (expected 30.0%)
[+862ms][CONN][RXD] PWM duty cycle of 40.0% produced an ADC reading of 39.6% (expected 40.0%)
[+914ms][CONN][RXD] PWM duty cycle of 50.0% produced an ADC reading of 50.8% (expected 50.0%)
[+966ms][CONN][RXD] PWM duty cycle of 60.0% produced an ADC reading of 60.4% (expected 60.0%)
[+1017ms][CONN][RXD] PWM duty cycle of 70.0% produced an ADC reading of 69.4% (expected 70.0%)
[+1069ms][CONN][RXD] PWM duty cycle of 80.0% produced an ADC reading of 80.0% (expected 80.0%)
[+1120ms][CONN][RXD] PWM duty cycle of 90.0% produced an ADC reading of 90.3% (expected 90.0%)
[+1172ms][CONN][RXD] PWM duty cycle of 100.0% produced an ADC reading of 100.0% (expected 100.0%)
[+1172ms][CONN][INF] found KV pair in stream: {{__testcase_finish;Test reading analog values with the ADC;1;0}}