Back to test-testshield-pwm-and-adc Results ^
Target: SFE_ARTEMIS
Test: test-testshield-pwm-and-adc
Test Case: Test PWM frequency and duty cycle (freq = 50 Hz)
{{__testcase_start;Test PWM frequency and duty cycle (freq = 50 Hz)}}, queued...
[+1531ms][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[+2626ms][SERI][TXD] {{frequency;50.0}}
[+2636ms][SERI][TXD] {{duty_cycle;0.4579738550653623}}
[+2666ms][CONN][RXD] Expected PWM frequency was 50 Hz (+- 20 Hz) and duty cycle was 45.85% (+-0.10%), host measured frequency 50 Hz and duty cycle 45.80%
[+2666ms][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[+3760ms][SERI][TXD] {{frequency;50.0}}
[+3770ms][SERI][TXD] {{duty_cycle;0.11859970350074125}}
[+3790ms][CONN][RXD] Expected PWM frequency was 50 Hz (+- 20 Hz) and duty cycle was 11.85% (+-0.10%), host measured frequency 50 Hz and duty cycle 11.86%
[+3801ms][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[+4896ms][SERI][TXD] {{frequency;50.0}}
[+4906ms][SERI][TXD] {{duty_cycle;0.840812897967755}}
[+4926ms][CONN][RXD] Expected PWM frequency was 50 Hz (+- 20 Hz) and duty cycle was 84.00% (+-0.10%), host measured frequency 50 Hz and duty cycle 84.08%
[+4936ms][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[+6063ms][SERI][TXD] {{frequency;50.0}}
[+6074ms][SERI][TXD] {{duty_cycle;0.9933750165624586}}
[+6094ms][CONN][RXD] Expected PWM frequency was 50 Hz (+- 20 Hz) and duty cycle was 99.34% (+-0.10%), host measured frequency 50 Hz and duty cycle 99.34%
[+6104ms][CONN][INF] found KV pair in stream: {{analyze_signal;please}}, queued...
[+7199ms][SERI][TXD] {{frequency;50.0}}
[+7209ms][SERI][TXD] {{duty_cycle;0.8077604805987985}}
[+7230ms][CONN][RXD] Expected PWM frequency was 50 Hz (+- 20 Hz) and duty cycle was 80.80% (+-0.10%), host measured frequency 50 Hz and duty cycle 80.78%
[+7240ms][CONN][INF] found KV pair in stream: {{__testcase_finish;Test PWM frequency and duty cycle (freq = 50 Hz);1;0}}